耐压/绝缘测试仪,耐压AC 0~5.000kV、0~30.00mA,DC 0~6.000kV、0~10.000mA,绝缘0.100~1.000kV、1~9999MΩ,测试时间0.5~999.9秒,内建8组高压矩阵式扫描信道。
产品特点
- 交/直流耐压、绝缘阻抗、接地阻抗测试
- 20×2 点矩阵 LCD 显示器
- 可选配内建4组或8组高压矩阵式扫描信道(7420, 7430 & 7440)
- 内建50组程序记忆、每一组8个测试步骤可进行程序记忆步骤的连结测试
- 测试线路阻抗自我归零校整功能,确保测试结果的准确性
- 前面板软件输入校正
- 内建PLC Remote遥控界面
- 键盘锁定功能
- 可外接标准GPIB/RS232/Print Card界面作控制
- 全范围电压输出的稳压率在1%以内
技术参数
SPECIFICATIONS | |||||
MODEL | 7410 | 7412 | 7420 | 7430 | 7440 |
AC WITHSTAND VOLTAGE | |||||
Output Rating | 5KVAC/30mA | 5KVAC/20mA | 5KVAC/30mA | 5KVAC/40mA | 5KVAC/40mA |
| Range | Resolution | Accuracy | ||
Output Voltage,ACV | 0 - 5000 | 1 | ±(2% of setting + 5V) | ||
Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||||
Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 | ||||
Output Regulation | ± (1% of output + 5V), From no load to full load | ||||
SETTINGS | |||||
Hi-Limit AC Current, mA | 0-30.00 | 0-20.00 | 0-30.00 | 0-40.00 | 0-40.00 |
Resolution : 0.01, Accuracy : ±(2% of setting + 3counts) | |||||
Lo-Limit AC Current, mA | Range : 0 - 9.999 | ||||
Resolution : 0.001, Accuracy : ±(2% of setting + 3counts) | |||||
Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | ||
Dwell Time, second | 0, 0.3 - 999.9 | 0.1 | |||
Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | ||||
AC Current Offset, mA | 0 - 2.000 or Auto Set | ||||
DC WITHSTAND VOLTAGE | |||||
Output Rating | 6KVDC/9999μA | ||||
Output Voltage, DCV | 0 - 6000 | 1 | ±(2% of setting + 5V) | ||
Output Ripple | <5%(6KV/9999μA at Resistive Load) | ||||
SETTINGS | |||||
Hi-Limit DC Current, μA | 0 - 9999 | 1 | ±(2% of setting + 3counts) | ||
Lo-Limit DC Current, μA | 0 - 999.9 | 0.1 | ±(2% of setting + 3counts) | ||
Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | ||
Dwell Time, second | 0, 0.4 - 999.9 | 0.1 | |||
Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | ||||
DC Current Offset, ?A | 0 - 200.0 or Auto Set | ||||
Ramp High Current | ON/OFF, User Selection | ||||
Charge - Low Current, μA | 0 - 350.0 or Auto Set | ||||
Discharge Time | < 200 msec | ||||
INSULATION RESISTANCE | |||||
Output Rating | 1KVDC/9999MΩ | ||||
Output Voltage, DCV | 100 - 1000 | 1 | ±(2% of setting + 3V) | ||
Hi-Limit Resistance, MΩ | 0, 1 - 9999 (0=OFF) | 1 | ±(2% of setting+2counts)at 500-1000VDC, 1 -1000 MΩ | ||
Lo-Limit Resistance, MΩ | 1 - 9999 | 1 | |||
Delay Time, second | 0, 0.5 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | ||
Charge - Low Current, μA | 0 - 3.500 or Auto Set | ||||
GROUND BOND (7440 ONLY) | |||||
Output Rating | 30A/600mΩ, 8V | ||||
Output AC Current, A | 3.00 - 30.00 | 0.01 | ± (2% of setting +3 counts) | ||
Output AC Voltage, V | 3.00 - 8.00 | 0.01 | ± (2% of setting +3 counts) at Open circuit | ||
Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||||
SETTINGS | |||||
Hi-Limit Resistance, mΩ | 0 - 150 (3 - 30A) | 1 | ± (2% of setting +2 counts) | ||
Lo-Limit Resistance, mΩ | 0 - 600 (3 - 10A) | ||||
Lead Resistance Offset, mΩ | 0 -200 | 1 | ± (2% of setting +2 counts) | ||
Dwell Time, second | 0, 0.5 - 999.9 sec (0=continuous) | 0.1 | ±(0.1% + 0.05sec) | ||
MEASUREMENT | |||||
AC/DC Voltage, KV | 0 - 6.00 | 0.01 | ±(1.5% of reading + 1count) | ||
DC Voltage, V (IR) | 100 - 1000 | 1 | ±(1.5% of reading + 3V) | ||
AC CurrentRange, mA | 0-3.500 | 0-3.500 | 0-3.500 | 0-3.500 | 0-3.500 |
3.00-30.00 | 3.00-20.00 | 3.00-30.00 | 3.00-40.00 | 3.00-40.00 | |
AC Current Resolution, mA | 0.001/0.01 | ||||
AC Current Accuracy, mA | ± (2% of reading + 3counts) | ||||
DC Current Range, μA | 0-350.0 | 0.1 | ± (2% of reading + 3counts) | ||
300 - 3500 | 1 | ||||
3000-9999 | 10 | ||||
AC Current, A (GB) | 0 - 35.00 | 0.01 | ±(2% of reading+3counts) | ||
Resistance, , MΩ(IR) | 1 - 9999 | 0.001 | ±(8% of reading+2counts)at 100-500VDC, | ||
Resistance, , mΩ (GB) | 0 - 600 | 1 | ±(2% of reading+2counts) | ||
GENERAL | |||||
Input Voltage AC | 115/230Vac±15%, 50/60Hz ± 5%, Fuse 5A Slow for 7410/7412 model, 6.3A Slow for 7420/7430/7440 model | ||||
PLC Remote Control | Input : Test , Reset , Memory1.2.3 | ||||
Output : Pass , Fail , Processing | |||||
Memory | 50 memories, 8 steps/memory | ||||
Display | 20×2 LCD with back light | ||||
Key Lock | To prevent unauthorized alteration of the test Parameters | ||||
Calibration | Build-in software and external calibrated meters | ||||
Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. | ||||
Rear Panel Output | YES | YES | YES | YES | YES |
Built-in Scanner | - | - | 8channels | Option | Option |
External Scanner | YES | YES | YES | YES | YES |
Smart GFI | YES | YES | YES | YES | YES |
Analog Meter | - | YES | - | YES | YES |
RS232 Interface | Option | Option | Option | YES | YES |
GPIB Interface | Option | Option | Option | Option | Option |
Printer Interface | Option | Option | Option | Option | Option |
TUV-GS listed | - | YES | - | YES | YES |
CE Compliance | - | YES | - | YES | YES |
Environment | 0-40℃, 20-80%RH | ||||
Dimension (W×H×D) | 430×133×300 (mm) | 430×133×500( mm) | 430×133×500(mm) | ||
Net Weight | 12Kg | 18Kg | 22Kg | ||
STANDARD ACCESSORIES | |||||
Power Cord(10A) | ×1 | ||||
Fuses | ×2 (Including a spare contained in the fuse holder) | ||||
Hipot Test Lead ,1.5m(1101) | ×1 | ||||
Return Test Cable(1102) | ×1 - | ||||
Hipot Return Lead ,1.8m(1103) | - | - | - | - | ×1 |
Ground Bond Return Lead 30A ,1.5m(1104) | - | - | - | - | ×1 |
Hipot Output Link Lead ,1.5m(1109) | - | - | ×8 | - | - |
RS232 Link Cable 1.5m(1130) | - | - | - | ×1 | ×1 |
Disk ( RS232 test program ) | - | - | - | ×1 | ×1 |